- More products
Optical reflectometer Yokogawa AQ7270
Description:
New OTDR-reflectometer Yokogawa AQ7270 proves than perfection has no boundaries! It has practically all the advantages of the previous model (Yokogawa AQ7260), but even more compact, lightweight and quick in use. AQ7270 is characterized by a record-breaking small dead zone of detection as of today – 0.8 meter. Within a few seconds the reflectometer is switched on and operation can be started, and the inline function of high-speed automatic testing enables the first simplified test to be carried out by pushing just one button. OTDR-reflectometer Yokogawa AQ7270 is designed to facilitate work under conditions of lack of time and free space, when density of information system and price for idle time are very high.
Specification:
Model |
AQ7270 |
Display |
8.4-inch TFT LCD color display, 640х480 points |
Display horizontal axis |
|
View range, km |
0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400 |
Measurement of distances |
Distance between any two points are displayed at reflectogram as an eight-unit number |
Distance measurement error |
1 m or ‘distance’ *2*10-5 (the greater one) |
Readout resolution, cm |
1 (minimum) |
Sampling density, m |
0.05, 0.1, 0.2, 0.5, 1, 2, 4, 8, 16, 32 |
Number of points in reflectogram |
Up to 50000 points |
Range of group-refractive index |
1.30000 … 1.79999 with a step 0.00001 |
Display vertical axis |
|
Attenuation scale, dB/div. |
0.2; 0.5; 1; 2; 5; 7.5 |
Readout resolution, dB |
0.001 (minimum) |
Loss measurement |
Signal level is displayed a five-unit number in step 0.001 dB. Functions of loss measurement at fiber section, long attenuation, loss at local inhomogeneity |
Return loss measurement |
Functions of local inhomogeneity reflectometry, and measurement of total reflection factor at a line section |
Loss measurement error, dB/dB |
0.05 |
General characteristics |
|
Laser |
Laser of Class 1 М (standard IEC60825-1:2001) |
Optical pulse length |
3 ns, 10 ns, 20 ns, 50 ns, 100 ns, 200 ns, 500 ns, 1 mcs, 2 mcs, 5 mcs, 10 mcs, 20 mcs |
Optical fiber type |
SM 10/125 (ITU-T G.652) |
Optical connector |
Adapter SC/FC |
Memory |
Not less than 1000 “scan images”. Measurement results and settings can be saved at an auxiliary memory connected via interface USB 1.1. |
Interfaces |
USB 1.1 type А – for external memory and printer Ethernet – supports FTP protocol |
Network adapter |
100-240 V, 50/60 Hz, up to 70 W (when printer in use or battery charging); |
Battery |
Type: NiMH. Operation without recharging: about 6 hours (30 sec. of measurement every 10 minutes, in energy-saving mode). Charging duration: less than 5 hours. |
Operation temperature |
from 0 to +45°С (from 0 to +35°С at battery charging) |
Storage temperature |
from -20 to +60°С |
Relative humidity |
Not more than 85% (without condensation) |
Dimensions and weight |
about 287 mm х 197 mm х 85 mm (WхHхD), about 2.8 kg |
Accessories |
Battery, strap, network adapter, operating manual |
Optical modules for Yokogawa AQ7270 (factory-set):
Model |
735022 |
735023 |
Wavelength, nm |
1310/1550±25 |
1310/1550±25 |
Dynamic range (S/N=1), dB |
34/32 |
40/38 |
Event dead zone, m |
0.8 |
0.8 |
Attenuation dead zone, m |
7/8 |
7/8 |